HUMIDITY MEASUREMENT FROM 15% TO 95% AND TEMPERATURE RANGE FROM 0℃ TO 70℃
Measure humidity and temperature simultaneously with Kaye's new humidity logger. The ValProbe RT logger comes with RF technology to give users real-time data viewable on their Validation Console. With a humidity range of 15% to 95%,and a temperature range from 0℃ to 70℃,this logger has a wide range of capabilities for temperature and humidity mappings.
The ValProbe RT humidity logger is designed for accurate,convenient and reliable process measurement for pharmaceutical,biotech and medical device applications. The wireless design greatly simplifies monitoring and validation of severe and hard-to-reach environments.
FEATURES
APPLICATIONS
FIELD-REPLACEABLE DIGITAL SENSOR We designed this humidity logger with the end user in mind. At Kaye we understand that sending loggers back to the manufacturer for factory calibration,verifications,or repairs can slow down your production. That's why this new ValProbe RT logger is built with a field-replaceable digital sensor. This allows users to quickly and cost-effectively replace the sensor without having to send the entire logger back to the calibration lab. The sensors are pre-calibrated before being sent to the user,guaranteeing precision and accuracy right from the start.
EASY VERIFICATIONS IN YOUR LAB When verifying for temperature,simply attach the 1-meter sensor extension cable for easy verification in a drywell,like the Kaye LTR-150. This dry block allows users to verify up to 18 humidity/temperature ValProbe RT loggers at once,saving a substantial amount of time. Once the probe is inserted into the dry block,the ValProbe RT software will perform an automatic verification and verify the temperature at multiple set points,determining the accuracy of the logger.
Verifying relative humidity is also easy by using a portable humidity test chamber,which will evaluate the performance of multiple ValProbes at a time. The RT software will perform an automatic verification of the humidity sensors to show if the loggers have drifted. Additionally,reports can be generated automatically inside the ValProbe RT software,simplifying the process to review the report of the loggers.
These verifications can be performed on site as often as needed. And while doing this often does reduce your risk,we still recommend sending loggers to our ISO 17025 accredited laboratory at least once per year to perform an As-Found and calibrate the sensors. Upon lab calibration,our technicians will provide you with verification documentation that includes all pertinent information about the loggers.